Modules Programming Guide - 21
Table 4: PGM Option Programming
Event Group Feature Group Start # End #
PGM
Activation*
PGM1 [910] [911] [912] [913]
PGM2 [920] [921] [922] [923]
- +10 per PGM +10 per PGM +10 per PGM +10 per PGM
PGM8 [980] [981] [982] [983]
PGM
Deactivation*
PGM1 [914] [915] [916] [917]
PGM2 [924] [925] [926] [927]
- +10 per PGM +10 per PGM +10 per PGM +10 per PGM
PGM8 [984] [985] [986] [987]
*For a complete list of events, refer to the PGM programming section of your Digiplex or Digiplex EVO control panel’s programming guide.
PGM Delay Options
PGM Delay
(000 to 255)
Default: 005
PGM1 [918] [919]
Option [1]: ON = PGM delay
OFF = Latch (default)
Option [2]: ON = Minutes
OFF = Seconds (default)
PGM2 [928] [929]
- +10 per PGM +10 per PGM
PGM8 [988] [989]
[991] View Two-Way PGM tamper trouble (PGMs with the trouble will be indicated by their number)
[992] View Two-Way PGM supervision trouble (PGMs with the trouble will be indicated by their number)
Sections
[040] to [043]
View how many of the 32 remotes are used.
[040] = remotes 1 to 8; [043] = remotes 25 to 32.
To delete a remote, press the corresponding number until it’s no longer displayed in these sections.
[201] to [232]
Assigning remote controls to the MG-RTX3.
[201] = remote 01; [232] = remote 32
Enter the desired section and then press and hold a button on the remote control until you hear a confirmation beep.
[301] to [332]
Assign the remote controls to users by entering a user number (001 to 255) in the appropriate section (Users 001 to 255, Section [301]
= remote 01, section [332] = remote 32.)
[401] to [432]
Program the remote control or delete the remote control button programming.
[401] = remote 01; [432] = remote 32
______/ ______/ ______/ ______/ ______/ ______/ ______/ ______ (default: 15000000)
(see MG-REM1 instructions)
(see MG-REM2 instructions)
[0] = Button Disabled [8] = Panic 2† (Non-Medical)
[1] = Regular Arm [9] = Panic 3† (Fire)
[2] = Stay Arm [stay] = Smoke reset
[3] = Instant Arm [force] = Utility Key 1*
[4] = Force Arm [arm] = Utility Key 2*
[5] = Disarm [disarm] = Utility Key 3*
[6] = Stay/Instant Disarm [byp] = Utility Key 4*
[7] = Panic 1† (Police) [mem] = Utility Key 5*
[clear] = Exit without saving [enter] = Save data