LCD Keypad 9
5.3 PROGRAMMING USER ACCESS CODES
The System Master and Users with the Master feature can program User Access Codes with User Options and
Area Assignme nts. Figure 5.1 on pag e 9 describes the steps you would follow to program User A ccess Codes.
If the keypad emits a Rejection Be ep at any po int d uring the progra mming procedure, you may have chosen an
existing User Code or you do not have access to certain User Options (section 5.4) and Area Assignments (step 7
in Figure 5.1 on page 9). User’s with th e Master feature can only a ssign Use r Options and Area Assignments that
they are assigned to. For example, i f a User with the Master feature is assign ed User Option 1 and Are a 2, they can
only assig n Options 1 and Area 2 to a User Access Cod e.
Figure 5.1: Programming User Access Codes
Enter your [ACCESS CODE] (System Master Code or User Access Code with Master
feature).
Press [0] to enter the Programming Menu.
From Programming Menu, press [ACC].
Enter the 2-digit User Number you want to program; press the [T
TT
T] button to scroll the
list of codes then press [
ACC ] once the desired code appears on the screen.
Enter a User Code within the brackets.
Press the [S
SS
S] button to reach the User Options
screen.
NOTE: The User Code is a Personal Identification Number (P.I.N.).
Program the User Options by pressing the number on your keypad corresponding to
the User Option you wish to enable. The option is considered ON when the number
appears within the brackets
. Proceed to step 7 by pressing the [S
SS
S] button. For a
detailed description of the User Options refer to section 5.4 on page 11
.
Options [1] and [2] : Master Feature
[1] OFF = Master Feature disabled.
[1] ON, [2] OFF = User can only modify User
Access Codes.
[1] ON, [2] ON = User has full Master rights.
User can create, m odify, and program User
options, User Access Options and Area
Assignments.
Option [3]: Duress
Option [4]:Bypass
Option [5]:Arm Only
Option [6]: Stay and Instant Arm
Option [7]:Force Arm
Option [8]: OFF - Access keypad’s
Access keypad’s
partitions only
ON - Access any
partition assigned
to user